Home All Categories Contact Us Account Cart Checkout 


The Original Concrete Waterer

Shopping Cart
Qty 0
(Sales tax will be added if applicable) Total($) 0.00

Categories
All Categories 
Specials 
Cattle Waterers - Small
Livestock Waterers
Combination Waterers
Horse Waterers
Sheep/Calves/Pet Waterers
Parts

Home 
Trade Shows/Dealers 
Installation Diagram 
Tax Exempt Forms 
Account 
Cart 
Checkout 
Contact Us 

Leisure Products 

What's New
1. Lower Arm
2. Upper Arm
3. Base Screw
4. Plunger
5. Plunger Seat

Top Sellers
1. Thermostat - Adjustable
2. Heater Large 1000 Watts 120V
3. 4" x 5" Copper Float
4. Drain Plug #15
5. 6 in. Stainless Steel Float Rod

Please Call Our Office To Place Your Order: 1-712-263-2442 or 1-800-832-7383

Buy a Petersen Concrete Waterer and your worries are over!

The Durability of a Petersen Livestock Waterer does not rely solely on the 3/8" welded rebar cages and the 5000 P.S.I, strength concrete. Petersen's air-entrained concrete is designed for expansion and contraction during temperature changes to eliminate cracking and deterioration. Our five-year warranty insures you that once you own a Petersen Concrete Waterer, your worries are over!

  • Deluxe Hinged Hood
    Insulated, Hands-Free access year-round
  • Epoxy Coated
    The entire tank is coated inside and out for easier cleaning, maintenance, and protection
  • Large 3" Drains
    Quick-flush drains insure total cleanout through the drain
  • Large Access Doors
    Heavy Duty Insulated plastic doors, allows for easy installation and service
  • Extruded Polystyrene Insulation up to 2"
    Permanently bonded to concrete, has a much higher R value than expanded foam
  • Heat Pit
    (Available) 18" to 36" diameter, 4' to 12', Deep depending on region, insulate the top 24", protects riser pipe
  • Top Adjustable Thermostats and Heaters
    Grounded, C.S.A. Approved, Encaloy Sheath, Immersion type, 120 Volt, with just the right wattage for energy efficiency, 220 Volt Option
  • Smooth, Rounded Edges
    Eliminates injury to animals
  • All Brass Valves
    For fast reliable water recovery, meets grade A dairy requirements
  • Reinforced Concrete
    5,000 P.S.I. rebar reinforced, air-entrained, and painted black, for solar heat on sunny days
  • Air-tight Seal
    Roof cement or other, no bolts needed
 
  • Concrete Pad
    (Available) Eliminates play, keeps waterer clean

Wiring Diagram (Instructions Below)

HELPFUL INSTRUCTIONS ON INSTALLING & MAINTENANCE
OF PETERSEN LIVESTOCK WATERERS

THERMOSTAT: Is preset at the factory @ approx. 46 to 48 degrees F. Adjustable thermostats with setscrew on top can be turned up by turning the setscrew counter-clockwise and vise versa. 1/4 turn is 15 degrees (approx.).

HEATING ELEMENT: Your local electrical code must be followed. The diagram above will be helpful, to a qualified person, to make the initial hookup (Proper grounding is a must). The wiring should be routed away from heating elements.

AUXILIARY HEATER: If recommended, installed below ground level or inside
waterer to insure against pipe line freeze-up in adverse weather conditions. This is
especially necessary in situations where the heat pit beneath the waterer is not enough
to allow sufficient ground heat to keep the line from freezing. NOTE: Size of heat pit may
range from 12"-36" in diameter depending on geographical region.

KEEPING ELEMENTS CLEAN: Each season before reconnecting the elements, make sure the electricity is turned off. With the power turned off, remove water deposit buildup with steel wool or a wire brush. Keeping the heater and thermostat clean on an annual basis will help to maintain efficient heat and will greatly extend the life of the element.

SECURING WATERER TO PAD: It is recommended that the waterer be placed on a concrete pad. Before setting the waterer in place, use a generous amount of roofing tar or equal, on bottom edge of unit. When set in place, this will insure an airtight seal between the waterer and pad, helping to keep the waterer in position.

IMPORTANT OPTIONAL FEATURES AVAILABLE: Other products are available from manufacturer which will make installation and maintenance easier. These include Auxiliary Pipe Heaters, 18" Dia. Dual Wall Earth Tube (Heat Pit), and QuickConnect Water Hoses. These items may be purchased from your dealer or Petersen Mfg.

To print the Wiring Diagram you will need Adobe Acrobat Reader. 
Wiring Diagram

Order Online @ www.petersenwaterers.com 

Don't Settle for less than Petersen Quality!

We weren't born yesterday, and neither were you,. Imitation waterers cost less to purchase, but cost more to service and operate and will not last as long. Compare before buying and you will see that Petersen has the best built, most reliable livestock waterers on the market today.

Get the Original Concrete Waterer, Buy a Petersen!

Petersen Mfg. Co. Inc., Setting the Standard in Quality and Durability Since 1913.

 


The Durability of a Petersen Livestock Waterer does not rely solely on the 3/8" welded rebar cages and the 5000 P.S.I, strength concrete. Petersen's air-entrained concrete is designed for expansion and contraction during temperature changes to eliminate cracking and deterioration. Our five year warranty insures you that once you own a Petersen Concrete Waterer, Your worries are over !

Made in the USA
 
Please Contact Us if you are unable to find the item you need.
We accept Visa & Mastercard.
Privacy Policy/Terms and Conditions

Copyright © 2005 - 2024  Petersen Manufacturing Company, INC. All rights reserved.
2471 Hwy 30, P.O. Box 664
Denison, IA 51442
712·263·2442 or 1·800·832·7383

Powered by PPP Design